1 P 2 P 3 P 4 P 5 P 6P 7 P 8 P 9 P 10 P 11 P

This transmitter is the device which detect the liquid levelin the column an d transmit the signal to thedisplay, which makers the remote control poss ible.

Principle
In thetransmitter, leed sitches and resiste rs are installedat regular intervals as show n in the Fig.
When the float equipped with magnet appoaches the Ieed switchm the nearest leed switch will be closed.

With resistance between A and B, voltage change is detected in the transmitterand the signal is transmitt ed to the autside of ter converting voltage change into 4-20mA.

Therefore, The float position can be detected
.


 

 

 

 

 

 

 

 

 

 

Standard Specification.

Voltage
DC22-28V
Currency 4-20mA D.C
permissive resistance 0-750§Ù
Accuracy ¡¾2% F.S
Detectable range 300~2000mm

No
Name
Material
Quant
1
Terminal Box
Aluminium
 
2
Transmitter box
Stainless Steel
 
3
Float
Stainless Steel
 
4
Column
Stainless Steel
 

1
Center Distance (C to C)mm
2
Visible length(V/L)mm
3
Connecton
4
Material
Column
5
Flange
6
Drain side (Plug,Valve,Flange)
7
Conditon
Fluid
8
Press.OP/DES.(kg/§²)
9
Temp. OP/DES.¡É
10
Specific Gravity
11
Option
Scale(Y/N)
12
Leed switch(Y/N)
13
Transmitter(Y/N)